A cold, uncomfortable room can be easily warmed up and turned cosy with an electric heater that has a thermostat. In order to install an electric heater in the wall you need a list of tools and equipments which includes the following –

  • 4 in 1 screwdriver
  • Clamps
  • Circular saw
  • A non contact voltage tester
  • A utility knife
  • Extension cord
  • Cordless drill
  • Stud finder
  • Drywall saw
  • Lineman’s pliers and
  • A drill bit set

Now let us see what materials you will need for the job.

  • Thermostat
  • Drywall screws
  • Heater
  • 14/2 or 12/2 cable
  • Wire nuts
  • Remodelling boxes

In addition to that you will also require electrical tape and plywood to wrap up the job smoothly.

Installing an electric heater with thermostat

Is there a room or two in your home that simply remain cold and unwelcoming in chilly damp weather? If your central heating system proves inadequate to warm up that room then what you need is installing an electric heater there. Modern electric haters are easy to mount on the walls although you can also place it in the floor between the joists or along the baseboard. Installing a heater is neither actually very difficult, nor scary task by any means.

Heat generated from electricity is costlier than that generated from gas although the heaters and the items required for installation are quite reasonably priced. It is important to remember that electric heaters do not cater to main source of heat but provide auxiliary heat to the indoors of your home or office says an expert with years of experience in electric heater replacement. It is a good idea to put a room electric heater on a completely separate setback thermostat which automatically starts working when you reach home or use that particular room.

Wall mount electric heater with thermostat

Hard wiring a wall mounted electric heater is not a challenging task although it involves running a separate circuit to the main panel. A wall mount electric heater is much safer to use compared to those plug-in portable heaters. The plug-in portable variety gets an existing electrical circuit overloaded easily leading to electrical hazards. To ensure safety with a wall mount heater you must run a new 240 volts circuit as well as install a thermostat that is programmable. However you should not attempt including the circuit into your main electrical panel DIY yourself. That task is better left to a qualified and licensed electrician.

London’s Carpet Renaissance: Dive into Exceptional Cleaning Services

Usually residential properties possess enough capacity in their service panel to accommodate a new circuit to cater to an electric heater with thermostat.  If circuit breakers are installed then there must be two empty spaces for the breaker. Reading a fuse box is much complex and it is important that you check the panel by an electrician before setting off to install the heater. You should not forget applying for an electrical permit so that an authoritative expert can check your work once you are finished.   

Capacity of electric heaters is measured in wattage. While installing heaters that are up to 2,880 watts you need running a cable with two 14-gaufe wires. There should also be a ground wire which is technically called the 14-2 with ground. For heaters that are up to 3,840 watts you need to run 12-2 cable with ground.

Wiring plan to install a heater

A professional whom provides the service of electric heater repair near me in London shares this simple and standard wiring plan for heater instalment. To make the task easier to understand let us break it down into few simple steps.

Step 1 – locate the easiest route for the cable

Zero in upon a suitable location on the wall for the heater as well as the thermostat. Just above the location of the heater and the thermostat you have to push in about 12 inches of the wire through the drywall.

Step 2 – now drill through the top plate

At this stage you have to push the insulation aside in order to locate the coat hanger wire as well as the top plates of the wall. Experienced professionals who provide the service of storage heater replacement suggest at this stage drilling is needed to make a hole that measures about ¾ inch. Make sure to drill through the centre of the top plates, right at the locations of the heater and the thermostat.

Step 3 – you have to cut out the hole for heater installation

Use a stud finder to locate the wall studs and then cut out a hole in the size of the heater along with a stud. Screw in as well as glue a 12 inch block (measuring 2x4) to the dry wall but on the other side of the opening. As precautionary step first cut out a tiny hole and check for electrical wires. When you see all is okay then go for knocking out the bigger hole.

Step 4 – running the wire for the electric heater and the thermostat

At this stage you have to tape one of the cable ends to a weighted string that is about 8 ft in length. Drop all of the string through the hole and then push through about 7 ft of it. You should make sure to pull the string and the cable from down below. Leave about 2 ft of the cable hanging freely through that hole you cut out earlier explains a team of electric heating installers near me

While installing heaters you must take advantage of open spaces like an unfinished attic or a basement. First get the cable close and then fish it through your wall suggest the experts. Identify a location on the interior wall to mount your heater. Make sure there is sufficient space between the studs. It is important to maintain a safe distance from plumbing fixtures and heat vents. A typical heater requires about 4 inches of depth and therefore your selected wall cavity must have at least 2x4 framing for safe and seamless installation. Go through the manufacturer’s manual carefully and make sure about clearances around the gadget suggest experts working at the renowned Electric Works London. Never install it near curtains or above a towel bar to avoid catching on fire. There should not be any inflammable item within 3 ft from your heater. It is also important to place the thermostat away from the range of hot air.